Enrange MHR Instruction Manual
August 2014
Page 14 of 57
Figure 04: MHR with Con1 and Con2 connectors Figure 05: MHR Side View
2.3 INSTALLATION
1. Determine the location of your antenna from Figures 01-03 (antenna is designated
with red arrow). Be sure to mount receiver antenna in direct line-of-sight of
operator and free from all obstructions.
2. Do not mount receiver near high levels of electric noise, such as an unshielded
variable frequency drive, as it may cause minor interference.
3. Allow adequate room for mounting the receiver. Make sure to allow a minimum of 5”
between connector and nearest surface to allow for cable harness connections.
4. For best reception and to help protect connectors from moisture and water damage,
mount the receiver in an upright position. Mount with back flush against a flat surface
to protect vents from spray.
5. If obstructions can’t be cleared, or unit must be mounted inside a metal enclosure, the
remote antenna should be used (see Figure 01).
6. Do not enclose antenna in steel. For best reception, keep all metal objects away from
the antenna. Consult the factory for more information regarding your
application.
7. When mounting the receiver the unit should be torqued no more than 10-12 in-lbs.