Flex 12EX System Instruction Manual
December 2013
Page 18 of 48
52134 867
FUNCTION
LED 1LED 2LED 3LED 4
4.1.2 Push Button Functions with LED Display Settings
4.1.2.1 Standard Push Button (Transmitter Toggle)
Set transmitter toggle (latching output relay) function by adjusting the 8-position function
dip-switch located on the backside of the transmitter encoder board (refer to Fig. 09
below). The LED 1 through LED 4 shown inside the shaded box (see below) illustrates
which LED on the transmitter will light up when the designated push button (PB7 ~ PB12)
is pressed.
(Fig. 09)
DIP PB7 PB8 PB9 PB10 PB11 PB12
1
00000000 Normal Normal Normal Normal Normal Normal
2
00001001 Normal Normal Normal LED 4 Normal Normal
3
00001010 Normal Normal LED 3 LED 4 Normal Normal
4
00001011 Normal LED 2 LED 3 LED 4 Normal Normal
5
00001100 LED 1 LED 2 LED 3 LED 4 Normal Normal
6
00001101 Normal Normal Normal Normal Normal LED 4
7
00001110 Normal Normal Normal Normal LED 3 LED 4
8
00001111 Normal Normal Normal LED 2 LED 3 LED 4
9
00010000 Normal Normal LED 1 LED 2 LED 3 LED 4
* PB7…PB12 → Push button number
* Normal → Normal momentary contact
* LED 1…LED 4 → Transmitter toggled with designated LED Display