Seite 1 - User’s Manual

FLEX8EX User’s Manual INDUSTRIAL RADIO CONTROLS #5 Four Coins Drive, Canonsburg PA 15317, Phone 1-724-746-3313 Fax 1-724-746

Seite 2 - Table of Contents

Page 971423 56 8CHANNEL71 423 56 8 4. Function Settings A. TRANSMITTER HANDSET 1. System Channel Settings (Fig. 07)

Seite 3

Page 1052134 867FUNCTIONLED 1LED 2LED 3LED 4 2. Push Button Functions with LED Displays A. Standard Push Button Configuration (Transmitter Toggl

Seite 4 - 1. Introduction

Page 11 B. Standard Push Button Configuration (A/B Selector) There are four (4) different types of A/B selector sequence available on the Flex

Seite 5 - 2. Radio Controlled Safety

Page 12 C. Inline Push Button Configuration (Transmitter Toggle) The push button arrangement for inline push button setup starts from top to b

Seite 6 - A. TRANSMITTER HANDSET

Page 13 D. Inline Push Button Configuration (A/B Selector) There are four (4) different types of A/B selector sequence available on the Fle

Seite 7 - 2. Internal Illustration

Page 14 3. I-CHIP I-Chip functioned in a way that is very similar to a SIM card inside a mobile phone, which stores system information such as you

Seite 8

Page 151 2 3 4 5 6 7 871 423 56 8 B. RECEIVER UNIT 1. System Channel Settings (Fig. 12) Even though

Seite 9

Page 16F1 R1F/R2F1 F2R1 R2F1 F/R2R1 R1F1 F/R2 2. Output Relay Configurations a. Output Relay Types 1. Three (3) output relays per motion

Seite 10 - 4. Function Settings

Page 17F1 R1 F2 R2R2F2R1F1ONOFFR2F2R1F1 R2F2R1F1 2. 4-output relays configuration with Opened/Closed contact at 2nd speed At 2nd speed, only th

Seite 11 - LED 1LED 2LED 3LED 4

Page 18OFF3rdSPEED d. START/AUX Function After initiating the START function the Start position will become an auxiliary function with momentary co

Seite 12

Page 1 Table of Contents Page 1. Introduction 3 2. Radio Controlled Safety 4 3. General System Inform

Seite 13

Page 19AuxSTOP41 32 65 874132 65 874231 785641 2 3 65 78 j. Auxiliary STOP Push Button Function The auxiliary STOP function acts as a 2nd emergen

Seite 14

Page 20RELAY FUNCTIONS1 324 756 8 4. Dip-Switch Settings a. Interlocked Functions Interlocked means the two adjacent push buttons can not be acti

Seite 15 - 3. I-CHIP

Page 21 b. Non-Interlocked Functions Contrary to interlocked settings, non-interlocked settings allow the two adjacent push buttons be used simulta

Seite 16 - B. RECEIVER UNIT

Page 22JP7JP1JP5JP3JP2JP4JP6 5. Jumper Settings Jumper settings are applied to functions such as mainline-disconnect time, Start function, transmitt

Seite 17 - F1 F2R1 R2

Page 23COM 1 2 3 4 6. I-CHIP Programming Port (Fig. 17) I-CHIP programming port located on the decoder module (refer to Fig. 17 above) i

Seite 18 - F1 R1 F2 R2R2F2R1F1

Page 24 5. System Channels Table Channel Frequency Dip-switch Setting Channel Frequency Dip-switch Setting 01 433.000MHZ 000000 32 433.775MHZ 1000

Seite 19

Page 25// 6. Receiver Installation A. OUTPUT RELAY CONTACT DIAGRAM * For 3-relay (shared 2nd speed) and 4-relay (se

Seite 20 - 41 32 65 87

Page 26 B. PRE-INSTALLATION PRECAUTIONS 1. Make sure the transmitter and receiver are with identical serial number/ID code and channel. 2. Mak

Seite 21 - 1 324 756 8

Page 27432 mmControlPanel 1. For best reception the location of the receiver should be visible to the operator at all time. 2. The location sel

Seite 22

Page 28 7. Operating Procedure A. TRANSMITTER OPERATION 1. General Operating Procedure a. Reset the red emergency stop button located on the t

Seite 23 - 5. Jumper Settings

Page 2 3. Receiver Auto-Scanning Settings 19 4. Dip-switch Settings a. Interlocked Functions 20 b. Non-interlocked Functions

Seite 24 - COM 1 2 3 4

Page 29AB3rdSPEED e. Now press any push button on the transmitter handset to operate the crane or equipment. f. In case of an emergency, press

Seite 25 - 5. System Channels Table

Page 30ONOFFCATCHCATCHCATCHPITCHPITCH12 4. Pitch & Catch Operating Procedure To release control of the crane, press the “Pitch” push button.

Seite 26 - 6. Receiver Installation

Page 31 B. STATUS LIGHT INDICATORS & WARNINGS 1. Transmitter STATUS Light Indication Type Display Type (Green & Red) Indication Voltage

Seite 27

Page 32 2. Receiver STATUS Light Indication Type Display Type (Green & Red) Indication 1 Fast green blinks Decoding in process 2 Slow gree

Seite 28 - D. SYSTEM TESTING

Page 33 C. TROUBLE SHOOTING TIPS Problems Possible Reasons Suggestions Transmitter low battery power Check the transmitter battery level. Emergen

Seite 29 - 7. Operating Procedure

Page 34 8. System Specifications Frequency Range : 433 ~ 434 MHz Number of Channels : 62 channels Channel Spacing : 25 KHz Mo

Seite 30

Page 35 9. Spare Parts 1. Transmitting Module (433/434MHz) TRB 01 2. Encoder Board (complete with push buttons) ENB 05 3. I

Seite 31

Page 36 Memo

Seite 32

Page 3 1. Introduction The FLEX radio remote control systems are designed for control of industrial equipment and machinery such as overhead trave

Seite 33

Page 4 2. Radio Controlled Safety Flex radio remote control system should be operated by persons with sufficient amount of knowledge and skill in c

Seite 34 - C. TROUBLE SHOOTING TIPS

Page 5 3. General System Information A. TRANSMITTER HANDSET 1. External Illustration (Standard Push Button Configuration)

Seite 35 - 8. System Specifications

Page 6 2. Internal Illustration (Fig. 03) (Fig. 04) 1. Encoder Board 6.

Seite 36 - 9. Spare Parts

Page 7 B. RECEIVER UNIT 1. External Illustration (Fig. 05) 1. Shock Mount 6. COM LED Display

Seite 37

Page 8 2. Internal Illustration (Fig. 06) 1. AC Line Filter 4. Decoder Modu